Siemens 6FX1130-6BA00 – I/O-INTERFACE 48A; 0,5A 3
Siemens 6FX1130-6BA00 – I/O-INTERFACE 48A; 0,5A 3 from the SINUMERIK range. Status: discontinued by the manufacturer, no longer available new since December 2007. Van Haelen supplies it new in sealed factory packaging, with a 24-month warranty.
Also written as: 6FX1 130-6BA00, 6FX11306BA00
The Siemens 6FX1130-6BA00 is a frequency converter or servo drive from the Sinumerik range. Manufacturer type designation: I/O-INTERFACE 48A; 0,5A 3. Status: discontinued by the manufacturer, no longer available new since December 2007. Key data: weight 0.38 kg, HS code 85389091. When replacing, keep the parameter set of the old unit; it makes setting up the replacement quick. Ask us about exchange, repair and a spare-parts pool for your installation.
Available as
Product data
| Manufacturer | Siemens |
|---|
| Part number | 6FX1130-6BA00 |
|---|
| Type designation | I/O-INTERFACE 48A; 0,5A 3 |
|---|
| Series | SINUMERIK |
|---|
| Manufacturer status | discontinued by the manufacturer, no longer available new since December 2007 |
|---|
| ETIM | EC002584 |
|---|
| HS code | 85389091 |
|---|
| Country of origin | DE |
|---|
| Weight | 0,38 kg |
|---|
Documentation from the manufacturer
All products of the SINUMERIK series
Faults and fixes 6FX1130-6BA00
Problems with 6FX1130-6BA00: overcurrent, overvoltage or overtemperature
On frequency converters and servo amplifiers three fault groups are the most common. Overcurrent: short circuit or earth fault in motor or cable, too short a ramp or wrong motor data; if the fault returns with no motor, the output stage is defective. DC-link overvoltage: decelerating too fast without a braking resistor. Overtemperature: a clogged heat sink or a fan that no longer turns. Always note the fault code and the moment.
What do I check when replacing a 6FX1130-6BA00?
Keep the parameter set of the old unit; it makes setting up the replacement quick. Check rating, supply voltage, frame and option boards, and whether the firmware version matches the parameter set. After long storage the DC-link capacitors should be reformed.
Fault not fixed: replace, exchange or repair the 6FX1130-6BA00?
Replacing from stock is the fastest route when a machine is down. Van Haelen supplies the 6FX1130-6BA00 new in factory packaging, with a 24-month warranty. The current lead time is shown with the condition on this page. Prefer an exchange: you get a refurbished unit straight away and return the faulty one within 14 days. Repairing your own unit is also possible: diagnosis, then a fixed price.
What information should I send for a quick diagnosis?
A photo of the rating plate (order number, product version, firmware), the exact fault code or LED state, when the fault occurs (at power-up, on enable, under load) and what you have already tried. For PLCs an export of the diagnostic buffer, for drives the parameter set. With that we can usually say the same day whether replacing, exchanging or repairing is best.
Frequently asked questions
Is the 6FX1130-6BA00 still available?
Not new from the manufacturer any more: the 6FX1130-6BA00 was discontinued since December 2007. Van Haelen supplies it from stock.
What should I check when replacing a 6FX1130-6BA00?
Keep the parameter set of the old unit; it makes setting up the replacement quick. Also check power rating, supply voltage and any option boards.