Siemens 6SE6440-2AB17-5AA1 – MICROMASTER 440
Siemens 6SE6440-2AB17-5AA1 – MICROMASTER 440 from the 440 range. Status: discontinued by the manufacturer, no longer available new since October 2019. Van Haelen supplies it refurbished or new in sealed factory packaging, with a 24-month warranty.
Also written as: 6SE6 440-2AB17-5AA1, 6SE64402AB175AA1
The Siemens 6SE6440-2AB17-5AA1 is a frequency converter or servo drive from the Micromaster (440) range. Manufacturer type designation: MICROMASTER 440. Status: discontinued by the manufacturer, no longer available new since October 2019. Key data: weight 1.3 kg, dimensions 19,00 x 9,00 x 18,00 cm, HS code 85044095. When replacing, keep the parameter set of the old unit; it makes setting up the replacement quick. Ask us about exchange, repair and a spare-parts pool for your installation.
Available as
Product data
| Manufacturer | Siemens |
|---|
| Part number | 6SE6440-2AB17-5AA1 |
|---|
| Type designation | MICROMASTER 440 |
|---|
| Series | 440 |
|---|
| Manufacturer status | discontinued by the manufacturer, no longer available new since October 2019 |
|---|
| Predecessor | 6SE3213-6BA40 |
|---|
| ETIM | EC001857 |
|---|
| HS code | 85044095 |
|---|
| Country of origin | GB |
|---|
| Weight | 1,3 kg |
|---|
| Dimensions | 19,00 x 9,00 x 18,00 cm |
|---|
Documentation from the manufacturer
All products of the 440 series
Faults and fixes 6SE6440-2AB17-5AA1
Fault F0001 on the MICROMASTER 440 (6SE6440-2AB17-5AA1): what does it mean?
According to Siemens' fault list F0001 is "Overcurrent" (STOP II). Causes Siemens names: short-circuit at the output; ground fault; excessively large motor (the motor power rating P0307 is greater than the inverter power r0206). Check first: are the cable lengths within the limit values; does the motor cable or motor have either a short-circuit or ground fault; do the motor parameters correspond to those of the motor being used. The full description is in the manual (link below). If the fault remains after these checks, the 6SE6440-2AB17-5AA1 needs replacing or repairing: we supply it refurbished from stock, with a test report and a 24-month warranty.
Source: Parameter List: MICROMASTER 440 (Siemens, p. 312)
Fault F0002 on the MICROMASTER 440 (6SE6440-2AB17-5AA1): what does it mean?
According to Siemens' fault list F0002 is "Overvoltage" (STOP II). Causes Siemens names: DC link voltage (r0026) higher than the overvoltage threshold (refer to parameter r0026); ground fault. Check first: is the line supply voltage within the permissible range; has the DC current DC link monitoring been enabled (P1240) and correctly parameterized; extend the deceleration ramp (ramp-down time P1121, P1135). The full description is in the manual (link below). If the fault remains after these checks, the 6SE6440-2AB17-5AA1 needs replacing or repairing: we supply it refurbished from stock, with a test report and a 24-month warranty.
Source: Parameter List: MICROMASTER 440 (Siemens, p. 312)
Fault F0003 on the MICROMASTER 440 (6SE6440-2AB17-5AA1): what does it mean?
According to Siemens' fault list F0003 is "Undervoltage" (STOP II). Causes Siemens names: line voltage failed; shock stressing outside the permissible limits. Check first: is the line supply voltage within the permissible range; is the line supply voltage stable with respect to sporadic failures and voltage dips (brown-outs). The full description is in the manual (link below). If the fault remains after these checks, the 6SE6440-2AB17-5AA1 needs replacing or repairing: we supply it refurbished from stock, with a test report and a 24-month warranty.
Source: Parameter List: MICROMASTER 440 (Siemens, p. 313)
Fault F0004 on the MICROMASTER 440 (6SE6440-2AB17-5AA1): what does it mean?
According to Siemens' fault list F0004 is "Inverter overtemperature" (STOP II). Causes Siemens names: inadequate cooling; ambient temperature is too high; ambient temperature is too high. Check first: is the pulse frequency P1800 set to the factory setting ? If required reset P1800; does the ambient temperature lie within the permissible limits; reduce the load and / or ensure adequate cooling. The full description is in the manual (link below). If the fault remains after these checks, the 6SE6440-2AB17-5AA1 needs replacing or repairing: we supply it refurbished from stock, with a test report and a 24-month warranty.
Source: Parameter List: MICROMASTER 440 (Siemens, p. 313)
Fault F0005 on the MICROMASTER 440 (6SE6440-2AB17-5AA1): what does it mean?
According to Siemens' fault list F0005 is "Inverter I2T" (STOP II). Causes Siemens names: inverter overloaded; load duty cycle too high; the motor power rating (P0307) is greater than that of the inverter (r0206). Check first: does the load duty cycle lie within the permissible limits; use a motor with a lower rating (motor power P0307 is greater than ls inverter power r0206). The full description is in the manual (link below). If the fault remains after these checks, the 6SE6440-2AB17-5AA1 needs replacing or repairing: we supply it refurbished from stock, with a test report and a 24-month warranty.
Source: Parameter List: MICROMASTER 440 (Siemens, p. 313)
Fault F0011 on the MICROMASTER 440 (6SE6440-2AB17-5AA1): what does it mean?
According to Siemens' fault list F0011 is "Motor overtemperature" (STOP II). Causes Siemens names: Motor overloaded. Check first: is the load cycle correct; are the rated/nominal motor overtemperatures correct (P0626-P0628); is the alarm threshold correct for the motor temperature (P0604). The full description is in the manual (link below). If the fault remains after these checks, the 6SE6440-2AB17-5AA1 needs replacing or repairing: we supply it refurbished from stock, with a test report and a 24-month warranty.
Source: Parameter List: MICROMASTER 440 (Siemens, p. 313)
Fault F0022 on the MICROMASTER 440 (6SE6440-2AB17-5AA1): what does it mean?
According to Siemens' fault list F0022 is "Hardware monitoring active" (STOP II). Causes Siemens names: This fault (r0947 = 22 and r0949 = 1) occurs under the following circumstances:; (1) DC link overcurrent condition = IGBT short-circuit; (2) Braking chopper short-circuit. Check first: You must first identify as to whether the fault is permanent (i.e. the inverter cannot be started without the; fault occurring) or it sporadically occurs (occasionally occurs or under certain operating conditions). The full description is in the manual (link below). If the fault remains after these checks, the 6SE6440-2AB17-5AA1 needs replacing or repairing: we supply it refurbished from stock, with a test report and a 24-month warranty.
Source: Parameter List: MICROMASTER 440 (Siemens, p. 314)
Fault F0041 on the MICROMASTER 440 (6SE6440-2AB17-5AA1): what does it mean?
According to Siemens' fault list F0041 is "Failure, motor data identification" (STOP II). Causes Siemens names: Motor data identification run unsuccessful (refer to fault value r0949):; r0949 = 0: Load missing; r0949 = 1: Current limit was reached during the identification run. Check first: r0949 = 0: Is the motor connected to the inverter; r0949 = 1-40: Is the motor data in P0304-P0311 correct; r0949 = 1-40: Motor circuit configuration correct (star, delta configuration). The full description is in the manual (link below). If the fault remains after these checks, the 6SE6440-2AB17-5AA1 needs replacing or repairing: we supply it refurbished from stock, with a test report and a 24-month warranty.
Source: Parameter List: MICROMASTER 440 (Siemens, p. 316)
Problems with 6SE6440-2AB17-5AA1: F0001, F0002 or F0003
On the MICROMASTER 4 F0001 is overcurrent (short circuit or earth fault in motor or cable, too short a ramp, wrong motor data), F0002 DC-link overvoltage (too short a deceleration ramp, mains too high) and F0003 undervoltage (mains gone or sagging). If F0001 returns immediately on enable with no motor connected, the output stage is defective.
6SE6440-2AB17-5AA1: F0004, F0005 or F0011, temperature and overload
F0004 is drive overtemperature (heat sink), F0005 thermal overload I²t of the drive, F0011 motor overload according to the thermal model. Clean heat sink and fan and check the ambient temperature; for F0011 the motor load and the set motor current (P0305). A failing fan is the most common wear item on this series.
6SE6440-2AB17-5AA1: F0022, power stack hardware fault
F0022 reports a fault in the power stack (current measurement, IGBT or gate drive) and can rarely be cured with a parameter. Check the motor cable for a short circuit; if the message persists, the drive is defective. A refurbished unit with the parameter set carried over is then the fastest way to get the machine running again.
What do I check when replacing a 6SE6440-2AB17-5AA1?
Read out the parameter set with the BOP, AOP or STARTER before removing the old drive; without it you must enter the motor data and I/O configuration again. Check rating, voltage and frame size and whether a filter or braking resistor belongs to it. After long storage the DC-link capacitors should be reformed; ask us about it.
Fault not fixed: replace, exchange or repair the 6SE6440-2AB17-5AA1?
Replacing from stock is the fastest route when a machine is down. Van Haelen supplies the 6SE6440-2AB17-5AA1 refurbished (tested, with a test report per serial number) or new in factory packaging, with a 24-month warranty. The current lead time is shown with the condition on this page. Prefer an exchange: you get a refurbished unit straight away and return the faulty one within 14 days. Repairing your own unit is also possible: diagnosis, then a fixed price.
What information should I send for a quick diagnosis?
A photo of the rating plate (order number, product version, firmware), the exact fault code or LED state, when the fault occurs (at power-up, on enable, under load) and what you have already tried. For PLCs an export of the diagnostic buffer, for drives the parameter set. With that we can usually say the same day whether replacing, exchanging or repairing is best.
Frequently asked questions
Is the 6SE6440-2AB17-5AA1 still available?
Not new from the manufacturer any more: the 6SE6440-2AB17-5AA1 was discontinued since October 2019. Van Haelen supplies it refurbished and tested.
Does the 6SE6440-2AB17-5AA1 replace the 6SE3213-6BA40?
Yes. According to the manufacturer the 6SE6440-2AB17-5AA1 is the successor of the 6SE3213-6BA40. Before replacing, check that the project and the connections match the new version; if in doubt we also supply the 6SE3213-6BA40 itself, refurbished or new, as long as it can be found.
What does refurbished mean?
Cleaned, inspected, aged or critical components replaced and tested to our test protocol for this product family. You get a 24-month warranty, a test report and a serial number label.
What should I check when replacing a 6SE6440-2AB17-5AA1?
Keep the parameter set of the old unit; it makes setting up the replacement quick. Also check power rating, supply voltage and any option boards.
Can I exchange or repair my faulty unit?
Yes. With an exchange Van Haelen supplies a refurbished unit straight away and you return the faulty one. With a repair you first get a diagnosis and then a fixed price, with test report and warranty.