Siemens 6SL4112-0JP18-0AF0 – G220 IP55 3AC200V 15kW FSD2
Siemens 6SL4112-0JP18-0AF0 – G220 IP55 3AC200V 15kW FSD2 from the G220 range. Status: active in the manufacturer's range. Van Haelen supplies it new in sealed factory packaging, with a 24-month warranty.
Also written as: 6SL4 112-0JP18-0AF0, 6SL41120JP180AF0
The Siemens 6SL4112-0JP18-0AF0 is a frequency converter or servo drive from the Sinamics (G220) range. Manufacturer type designation: G220 IP55 3AC200V 15kW FSD2. Status: active in the manufacturer's product range. Key data: weight 33.9 kg, dimensions 80,00 x 40,00 x 46,50 cm, HS code 85044095. When replacing, keep the parameter set of the old unit; it makes setting up the replacement quick. Ask us about exchange, repair and a spare-parts pool for your installation.
Available as
Product data
| Manufacturer | Siemens |
|---|
| Part number | 6SL4112-0JP18-0AF0 |
|---|
| Type designation | G220 IP55 3AC200V 15kW FSD2 |
|---|
| Series | G220 |
|---|
| Manufacturer status | active in the manufacturer's range |
|---|
| ETIM | EC002584 |
|---|
| HS code | 85044095 |
|---|
| Country of origin | DE |
|---|
| Weight | 33,9 kg |
|---|
| Dimensions | 80,00 x 40,00 x 46,50 cm |
|---|
Documentation from the manufacturer
All products of the G220 series
Faults and fixes 6SL4112-0JP18-0AF0
Problems with 6SL4112-0JP18-0AF0: overcurrent, overvoltage or overtemperature
On frequency converters and servo amplifiers three fault groups are the most common. Overcurrent: short circuit or earth fault in motor or cable, too short a ramp or wrong motor data; if the fault returns with no motor, the output stage is defective. DC-link overvoltage: decelerating too fast without a braking resistor. Overtemperature: a clogged heat sink or a fan that no longer turns. Always note the fault code and the moment.
What do I check when replacing a 6SL4112-0JP18-0AF0?
Keep the parameter set of the old unit; it makes setting up the replacement quick. Check rating, supply voltage, frame and option boards, and whether the firmware version matches the parameter set. After long storage the DC-link capacitors should be reformed.
Fault not fixed: replace, exchange or repair the 6SL4112-0JP18-0AF0?
Replacing from stock is the fastest route when a machine is down. Van Haelen supplies the 6SL4112-0JP18-0AF0 new in factory packaging, with a 24-month warranty. The current lead time is shown with the condition on this page. Prefer an exchange: you get a refurbished unit straight away and return the faulty one within 14 days. Repairing your own unit is also possible: diagnosis, then a fixed price.
What information should I send for a quick diagnosis?
A photo of the rating plate (order number, product version, firmware), the exact fault code or LED state, when the fault occurs (at power-up, on enable, under load) and what you have already tried. For PLCs an export of the diagnostic buffer, for drives the parameter set. With that we can usually say the same day whether replacing, exchanging or repairing is best.
Frequently asked questions
Is the 6SL4112-0JP18-0AF0 still available?
Yes. The 6SL4112-0JP18-0AF0 is still in the manufacturer's range.
What should I check when replacing a 6SL4112-0JP18-0AF0?
Keep the parameter set of the old unit; it makes setting up the replacement quick. Also check power rating, supply voltage and any option boards.