Siemens 6SN1118-1NJ00-0AA2
Siemens 6SN1118-1NJ00-0AA2 – Drive modules (control units, power and line modules) from the 611 range. Status: discontinued by the manufacturer, no longer available new; successor 6SN1118-1NJ01-0AA0. Van Haelen supplies it refurbished, with a 24-month warranty.
Also written as: 6SN1 118-1NJ00-0AA2, 6SN11181NJ000AA2
The Siemens 6SN1118-1NJ00-0AA2 is a frequency converter or servo drive from the Simodrive (611) range. Status: discontinued by the manufacturer, no longer available new; successor according to the manufacturer: 6SN1118-1NJ01-0AA0. Key data: weight 0.8 kg, dimensions 36,00 x 20,00 x 8,00 cm, HS code 85049099. When replacing, keep the parameter set of the old unit; it makes setting up the replacement quick. Ask us about exchange, repair and a spare-parts pool for your installation.
Available as
Product data
| Manufacturer | Siemens |
|---|
| Part number | 6SN1118-1NJ00-0AA2 |
|---|
| Series | 611 |
|---|
| Manufacturer status | discontinued by the manufacturer, no longer available new |
|---|
| Predecessor | 6SN1118-1NJ00-0AA1 |
|---|
| Successor | 6SN1118-1NJ01-0AA0 |
|---|
| ETIM | EC001857 |
|---|
| HS code | 85049099 |
|---|
| Country of origin | DE |
|---|
| Weight | 0,8 kg |
|---|
| Dimensions | 36,00 x 20,00 x 8,00 cm |
|---|
Documentation from the manufacturer
All products of the 611 series
All Drive modules
Faults and fixes 6SN1118-1NJ00-0AA2
Problems with 6SN1118-1NJ00-0AA2: red LED on the I/R module, no DC-link voltage
On SIMODRIVE 611 the infeed/regenerative module (I/R, UI) builds up the 600 V DC link. A red LED on that module means a fault: mains or a phase missing, the enables on terminals 63 (pulse enable), 64 (controller enable) and 48 (line contactor) absent, or the module itself defective. Check mains and enables first; without the DC link every axis module reports a fault.
6SN1118-1NJ00-0AA2: alarm 300xxx on the SINUMERIK or fault number on the 611U display
The 300xxx alarms of the 840D/810D belong to the 611D drive and name the axis and the cause (encoder, current, temperature, enable). On the 611U the fault number is on the drive's display. Note alarm, axis and the moment (at power-up, on enable, under load): that is what separates a cable or encoder fault from a defective module.
What do I check when replacing a 6SN1118-1NJ00-0AA2?
On 611 modules the full order number counts: current, number of axes and the control board (611A, 611D, 611U) must be identical. Carry over the control board on 611D and the parameter set on 611U. Check the DC-link bars and the device-bus ribbon cable; a poor bus connection gives the same alarms as a defective module.
Fault not fixed: replace, exchange or repair the 6SN1118-1NJ00-0AA2?
Replacing from stock is the fastest route when a machine is down. Van Haelen supplies the 6SN1118-1NJ00-0AA2 refurbished: tested to this family's test protocol, with a test report per serial number, with a 24-month warranty. The current lead time is shown with the condition on this page. Prefer an exchange: you get a refurbished unit straight away and return the faulty one within 14 days. Repairing your own unit is also possible: diagnosis, then a fixed price.
What information should I send for a quick diagnosis?
A photo of the rating plate (order number, product version, firmware), the exact fault code or LED state, when the fault occurs (at power-up, on enable, under load) and what you have already tried. For PLCs an export of the diagnostic buffer, for drives the parameter set. With that we can usually say the same day whether replacing, exchanging or repairing is best.
Frequently asked questions
Is the 6SN1118-1NJ00-0AA2 still available?
Not new from the manufacturer any more: the 6SN1118-1NJ00-0AA2 was discontinued. Van Haelen supplies it refurbished and tested.
What is the successor of the 6SN1118-1NJ00-0AA2?
According to the manufacturer it is the 6SN1118-1NJ01-0AA0. A successor does not always fit an existing installation without changes; replacing like for like is often the fastest route. If in doubt, ask us.
Does the 6SN1118-1NJ00-0AA2 replace the 6SN1118-1NJ00-0AA1?
Yes. According to the manufacturer the 6SN1118-1NJ00-0AA2 is the successor of the 6SN1118-1NJ00-0AA1. Before replacing, check that the project and the connections match the new version; if in doubt we also supply the 6SN1118-1NJ00-0AA1 itself, refurbished or new, as long as it can be found.
What does refurbished mean?
Cleaned, inspected, aged or critical components replaced and tested to our test protocol for this product family. You get a 24-month warranty, a test report and a serial number label.
Can I exchange or repair my faulty unit?
Yes. With an exchange Van Haelen supplies a refurbished unit straight away and you return the faulty one. With a repair you first get a diagnosis and then a fixed price, with test report and warranty.