Indramat DDS02.2-A100-BE12-01-FW – AC Servo Controller
Indramat DDS02.2-A100-BE12-01-FW – AC Servo Controller from the DDS range. Status: discontinued by the manufacturer, no longer available new. Van Haelen supplies it refurbished, with a 24-month warranty.
Also written as: DDS02.2A100BE1201FW
The Indramat DDS02.2-A100-BE12-01-FW is a Indramat/Bosch Rexroth drive component from the DIAX02 (DDS) range. Manufacturer type designation: AC Servo Controller. Status: discontinued by the manufacturer, no longer available new. Key data: weight 11 kg, dimensions 48,00 x 36,00 x 6,00 cm, HS code 85044095. When replacing, keep the parameter set of the old unit; it makes setting up the replacement quick. Ask us about exchange, repair and a spare-parts pool for your installation.
Available as
Product data
| Manufacturer | Indramat |
|---|
| Part number | DDS02.2-A100-BE12-01-FW |
|---|
| Type designation | AC Servo Controller |
|---|
| Series | DDS |
|---|
| Manufacturer status | discontinued by the manufacturer, no longer available new |
|---|
| ETIM | EC001857 |
|---|
| HS code | 85044095 |
|---|
| Weight | 11 kg |
|---|
| Dimensions | 48,00 x 36,00 x 6,00 cm |
|---|
Documentation from the manufacturer
All products of the DDS series
Faults and fixes DDS02.2-A100-BE12-01-FW
Problems with DDS02.2-A100-BE12-01-FW: F2xx or F8xx on the diagnostic display
Indramat and Rexroth drives (DKC, DDS, DKS) show their state on the H1 display: bb and Ab are ready states, an F code a fault. F2xx faults are mostly non-fatal (for instance excessive following error or an encoder fault), F8xx fatal (power section, overcurrent, earth fault). Note the code and consult the firmware's diagnostic list; the code says whether motor, encoder cable or drive is suspect.
What do I check when replacing a DDS02.2-A100-BE12-01-FW?
The firmware version (FWA number) and the drive configuration must match the old unit; on DKC drives the firmware is on a module you can carry over. Save the parameters with DriveTop or via the control and check motor type, encoder and brake control before enabling.
Fault not fixed: replace, exchange or repair the DDS02.2-A100-BE12-01-FW?
Replacing from stock is the fastest route when a machine is down. Van Haelen supplies the DDS02.2-A100-BE12-01-FW refurbished: tested to this family's test protocol, with a test report per serial number, with a 24-month warranty. The current lead time is shown with the condition on this page. Prefer an exchange: you get a refurbished unit straight away and return the faulty one within 14 days. Repairing your own unit is also possible: diagnosis, then a fixed price.
What information should I send for a quick diagnosis?
A photo of the rating plate (order number, product version, firmware), the exact fault code or LED state, when the fault occurs (at power-up, on enable, under load) and what you have already tried. For PLCs an export of the diagnostic buffer, for drives the parameter set. With that we can usually say the same day whether replacing, exchanging or repairing is best.
Frequently asked questions
Is the DDS02.2-A100-BE12-01-FW still available?
Not new from the manufacturer any more: the DDS02.2-A100-BE12-01-FW was discontinued. Van Haelen supplies it refurbished and tested.
What does refurbished mean?
Cleaned, inspected, aged or critical components replaced and tested to our test protocol for this product family. You get a 24-month warranty, a test report and a serial number label.
What should I check when replacing a DDS02.2-A100-BE12-01-FW?
Keep the parameter set of the old unit; it makes setting up the replacement quick. Also check power rating, supply voltage and any option boards.
Can I exchange or repair my faulty unit?
Yes. With an exchange Van Haelen supplies a refurbished unit straight away and you return the faulty one. With a repair you first get a diagnosis and then a fixed price, with test report and warranty.