Problems with MDSKABS112-22: F01, F06, F07 or F11 on the MOVIDRIVE
On SEW MOVIDRIVE and MOVITRAC F01 is overcurrent (short circuit, earth fault, too short a ramp), F06 a missing mains phase, F07 DC-link overvoltage (decelerating too fast without a braking resistor) and F11 drive overtemperature. F08 is the speed monitoring (motor does not follow, encoder or brake), F14 an encoder fault. Note the fault code and what the drive was doing at that moment.
What do I check when replacing a MDSKABS112-22?
Save the parameter set with MOVITOOLS or the keypad, and note the option boards (DFP, DFE, DIP) and their firmware; they define the fieldbus link. Rating, voltage and frame must be identical. After replacement check the brake control and the encoder setting before enabling the axis.
Fault not fixed: replace, exchange or repair the MDSKABS112-22?
Replacing from stock is the fastest route when a machine is down. Van Haelen supplies the MDSKABS112-22 refurbished: tested to this family's test protocol, with a test report per serial number, with a 24-month warranty. The current lead time is shown with the condition on this page. Prefer an exchange: you get a refurbished unit straight away and return the faulty one within 14 days. Repairing your own unit is also possible: diagnosis, then a fixed price.
What information should I send for a quick diagnosis?
A photo of the rating plate (order number, product version, firmware), the exact fault code or LED state, when the fault occurs (at power-up, on enable, under load) and what you have already tried. For PLCs an export of the diagnostic buffer, for drives the parameter set. With that we can usually say the same day whether replacing, exchanging or repairing is best.
Frequently asked questions
What does refurbished mean?
Cleaned, inspected, aged or critical components replaced and tested to our test protocol for this product family. You get a 24-month warranty, a test report and a serial number label.
What should I check when replacing a MDSKABS112-22?
Keep the parameter set of the old unit; it makes setting up the replacement quick. Also check power rating, supply voltage and any option boards.
Can I exchange or repair my faulty unit?
Yes. With an exchange Van Haelen supplies a refurbished unit straight away and you return the faulty one. With a repair you first get a diagnosis and then a fixed price, with test report and warranty.