Lenze MDSKAIG090-22
Lenze MDSKAIG090-22 – Frequentieregelaars from the LENZE range. Status: discontinued by the manufacturer, no longer available new. Van Haelen supplies it refurbished or new in sealed factory packaging, with a 24-month warranty.
Also written as: MDSKAIG09022
The Lenze MDSKAIG090-22 is a drive or controller. Status: discontinued by the manufacturer, no longer available new. When replacing, keep the parameter set of the old unit; it makes setting up the replacement quick. Ask us about exchange, repair and a spare-parts pool for your installation.
Available as
Product data
| Manufacturer | Lenze |
|---|
| Part number | MDSKAIG090-22 |
|---|
| Series | LENZE |
|---|
| Manufacturer status | discontinued by the manufacturer, no longer available new |
|---|
| ETIM | EC001857 |
|---|
Documentation from the manufacturer
All products of the LENZE series
Faults and fixes MDSKAIG090-22
Problems with MDSKAIG090-22: F01, F06, F07 or F11 on the MOVIDRIVE
On SEW MOVIDRIVE and MOVITRAC F01 is overcurrent (short circuit, earth fault, too short a ramp), F06 a missing mains phase, F07 DC-link overvoltage (decelerating too fast without a braking resistor) and F11 drive overtemperature. F08 is the speed monitoring (motor does not follow, encoder or brake), F14 an encoder fault. Note the fault code and what the drive was doing at that moment.
What do I check when replacing a MDSKAIG090-22?
Save the parameter set with MOVITOOLS or the keypad, and note the option boards (DFP, DFE, DIP) and their firmware; they define the fieldbus link. Rating, voltage and frame must be identical. After replacement check the brake control and the encoder setting before enabling the axis.
Fault not fixed: replace, exchange or repair the MDSKAIG090-22?
Replacing from stock is the fastest route when a machine is down. Van Haelen supplies the MDSKAIG090-22 refurbished (tested, with a test report per serial number) or new in factory packaging, with a 24-month warranty. The current lead time is shown with the condition on this page. Prefer an exchange: you get a refurbished unit straight away and return the faulty one within 14 days. Repairing your own unit is also possible: diagnosis, then a fixed price.
What information should I send for a quick diagnosis?
A photo of the rating plate (order number, product version, firmware), the exact fault code or LED state, when the fault occurs (at power-up, on enable, under load) and what you have already tried. For PLCs an export of the diagnostic buffer, for drives the parameter set. With that we can usually say the same day whether replacing, exchanging or repairing is best.
Frequently asked questions
Is the MDSKAIG090-22 still available?
Not new from the manufacturer any more: the MDSKAIG090-22 was discontinued. Van Haelen supplies it refurbished and tested.
What does refurbished mean?
Cleaned, inspected, aged or critical components replaced and tested to our test protocol for this product family. You get a 24-month warranty, a test report and a serial number label.
What should I check when replacing a MDSKAIG090-22?
Keep the parameter set of the old unit; it makes setting up the replacement quick. Also check power rating, supply voltage and any option boards.
Can I exchange or repair my faulty unit?
Yes. With an exchange Van Haelen supplies a refurbished unit straight away and you return the faulty one. With a repair you first get a diagnosis and then a fixed price, with test report and warranty.